CLIMATIC CHAMBER MANUFACTURER
TESTING CHAMBERS
CLIMATIC CHAMBER MANUFACTURER· TESTING CHAMBERS · Test chamber & Lab instrument · ENDURANCE TESTING CHAMBERS-Environmental …
Humidity Range: 10%RH to 98%RH Rate of Temperature Change(options): 1 °C/Min …
Test Standard Compliance: IEC-60068, ISO16.. .Maximum Temperature: 180°C

SPECIFICATIONS | SWN -40T | SWN-70T |
TEMPERATURE RANGE | – 40°C TO +180°C | – 70°C TO +180°C |
STANDARD VOLUME RANGE | 110 L, 225L, 270L, 450L, 580L, 1000L, 1500L | 110 L, 225L, 580L, 1000L, 1500L |
MINIMUM TEMPERATURE | -40°C | -70°C |
MAXIMUM TEMPERATURE | 180°C | 180°C |
RATE OF TEMPERATURE CHANGE(OPTIONS) | 1 °C/MIN TO 3°C/MIN, UPTO 20°C/MIN | 1 °C/MIN TO 3°C/MIN, UPTO 20°C/MIN |
HUMIDITY RANGE | 10%RH TO 98%RH | 10%RH TO 98%RH |
CUSTOMISABILITY | YES | YES |
REFRIGERATION SYSTEM | SINGLE | CASCADE |
LOW GWP REFRIGERANT (OPTION) | YES | YES |
TEST STANDARD COMPLIANCE | IEC-60068, ISO16750, ASTM, SAE, BIS & 50 OTHER STANDARDS |
TEST CHAMBER & LAB INSTRUMENT
WE OWN A RICH EXPERIENCE IN MANUFACTURING, TRADING, SUPPLYING AND DEALING EQUIPMENT AND ITS SPARES TO OUR CUSTOMERS. THESE PRODUCTS ARE THOROUGHLY CHECKED FOR QUALITY.
ENDURANCE TESTING CHAMBERS-CLIMATIC CHAMBER MANUFACTURER
TESTING EQUIPMENT’S
CLIMATIC TEST CHAMBERS
SALT SPRAY TEST CHAMBERS
ENVIRONMENTAL SIMULATION
HOT AND COLD CHAMBER
THERMAL CYCLING CHAMBER
HUMIDITY CHAMBER
WALK IN CHAMBER
MACHINERIES
HUMIDIFIER / DEHUMIDIFIER
INDUSTRIAL REFRIGERATOR
CUSTOMIZED CONTROL PANEL AND ITS ACCESSORIES
INDUSTRIAL CHILLER / PANEL COOLER
INDUSTRIAL FURNACES
THERMAL SHOCK CHAMBERS
BOILER SYSTEM
CALIBRATION BATH
CIRCULATING CHILLER
CLIMATIC CHAMBER MANUFACTURER
WHATS APP UP US THROUGH THIS LINK:HTTPS://WA.LINK/ZQXVLF
CLIMATIC CHAMBER MANUFACTURER IN CHENNAI-CAN CONTACT
TEL:09344410460
OTHER EQUIPMENTS
TESTING CHAMBERS:
CLIMATIC CHAMBERS, HOT AND COLD CHAMBER, THERMAL SHOCK CHAMBER, SALT SPRAY CHAMBER, HUMIDITY CHAMBER, STABILITY CHAMBER,THERMAL CYCLING CHAMBER,AGEING CHAMBER,COLD ROOM, PANEL/WATER/OIL COOLERS.
LABORATORY INSTRUMENTS:
HOT AIR OVEN, VACUUM OVEN, INCUBATOR, BOD INCUBATOR, CO2 INCUBATOR, ORBITAL SHAKING INCUBATOR, HOT PLATE, HEATING MANTLE, SOXHLET APPARATUS, WATER BATH, CENTRIFUGE, ELECTRONIC WEIGHING BALANCE, LABORATORY MIXERS/SHAKERS, AUTOCLAVE, DISTILLATION UNIT, ELECTRIC BUNSEN BURNER, FUME HOOD, BIO SAFETY CABINETS/ LAMINAR AIR FLOW, REFRIGERATORS AND AIR CONDITIONERS.
.
BLOOD BANK INSTRUMENTS:
DONOR COUCH, BLOOD COLLECTION MONITOR, TUBE SEALER, BLOOD BANK REFRIGERATOR, DEEP FREEZER, PLATELET AGITATOR/INCUBATOR, COMPONENT CENTRIFUGE, THAWING BATH, CRYO BATH, PLASMA EXPRESSOR, ELISA READER AND ELISA WASHER.
.
RESEARCH INSTITUTE INSTRUMENTS:
DEEP FREEZERS (-20°C, -40°C & -80°C), ICE MAKER, LYOPHILIZER (FREEZE DRYER), BOD INCUBATOR, CO2 INCUBATORS AND MUFFLE FURNACE.
LAB INSTRUMENTS
.
***WE ARE UNDER TAKING MANUFACTURING/REPAIR SERVICE/MODIFICATION/AMC/CAMC FOR ABOVE INSTRUMENTS &CHAMBER SERVICE IN CHENNAI AND BANGALORE***
OUR SERVICES-CLIMATIC CHAMBER MANUFACTURER
STEER WING NETWORK ALSO OFFERS A VARIETY OF PREVENTIVE MAINTENANCE, REPAIR AND UPGRADE PLANS THROUGH OUR DEDICATED SERVICE GROUP. CONSISTING OF EXPERIENCED TECHNICAL SERVICE AND ENGINEERING PERSONNEL, OUR SERVICE TEAM IS ON CALL FOR DOMESTIC CLIENTS FOR ANY REQUIREMENT. SOME OF THE SERVICES PROVIDED INCLUDE
ANNUAL PREVENTIVE MAINTENANCE CONTRACT PROGRAM
REPAIRING SERVICES
MANUFACTURING SUPPORT
AFTER SALES SUPPORT
CALIBRATION SERVICE
REFRIGERATION RETROFITS
REFURBISHING OF ANY MANUFACTURER’S UNIT AND/OR MODEL
CONTROL SYSTEM UPGRADES FOR ANY MANUFACTURER’S
SPARE PARTS ORDERS
INSTALLATION SERVICES OR INSTALLATION SUPERVISION
EQUIPMENT/FACILITY START-UP
EQUIPMENT OPERATOR TRAINING
ON CALL SERVICE SUPPORT 24*7-ENVIRONMENTAL CHAMBER MANUFACTURER IN CHENNAI
SO YOU CAN QUESTION US, TRUST US, JUDGE US AND EVEN PARTNER US IN BUILDING A TRULY GREAT SUPPORT. A JOURNEY THAT
CLIMATIC CHAMBER MANUFACTURER
PREVENTIVE MAINTENANCE SOLUTIONS-ENVIRONMENTAL CHAMBER MANUFACTURER IN CHENNAI
- THE NATURE OF SERVICE THAT WILL BE PROVIDED IN A ROUTINE MAINTENANCE CALL IS CLEANING, GENERAL CHECK-UP, FINE-TUNING AND MINOR ADJUSTMENTS REQUIRED.
- DURING THE AMC PERIOD, THE BELOW STEPS WILL BE CARRIED OUT BASED ON THE EQUIPMENT
REFRIGERATION SYSTEM
- CHECKING THE STANDING PRESSURE
- CHECKING OF THE OIL LEVEL IN COMPRESSOR.
- CLEANING OF CONDENSER COIL & CONDENSER COOLING FANS OPERATION.
- RECTIFICATION FOR ANY DAMAGED INSULATION.
- CHECKING THE FITMENT OF ALL SOLENOID VALVES, HAND SHUTOFF VALVES ETC.
- CHECKING OF THE OIL RETURN TO THE COMPRESSOR.
- CHECKING OF ELECTRICAL WIRING, TIMER SETTING, OVER LOAD SETTING.
- CHECKING OF THE REFRIGERATION COMPRESSOR.
- MONITORING OF SUCTION & DISCHARGE PRESSURE OF REFRIGERATION SYSTEM.-ENVIRONMENTAL CHAMBER MANUFACTURER IN CHENNAI
- CHECKING OF OPERATION & SETTING FOR ALL SAFETIES SUCH AS HP/LP, OIL PRESSURE, FLOW SWITCH ETC.
HEATING SYSTEM
- CHECKING THE PROPER FUNCTIONING OF THE RELAYS
- CHECKING THE OVER TEMPERATURE SAFETY AND ALARM
- MONITORING THE FLOWING CURRENT OF THE HEATERS.
- FUNCTIONAL CHECKING OF THE ENTIRE SYSTEM
GENERAL WORK
- OVERALL CLEANING OF THE EQUIPMENT
- CHECKING OF CONDENSER, FAN BLADES, CHAMBER AIR CIRCULATION FAN BLADE/ IMPELLER COMPRESSOR COOLING BLOWER, COMPRESSOR COOLING FAN BLADE, TIGHTEN THE BOLTS AND NUTS.
- CHECKING OF DOOR GASKET AND DOOR SEALS.
- CHECKING AND ADJUSTING OF DOOR HINGES AND LATCHES, IF REQUIRED.
- CHECKING OF REFRIGERATION COMPRESSOR.
- CHECKING OF PRESSURE AND OIL SWITCHES AND THEIR SETTINGS.
- CHECKING OF ELECTRICAL WIRING, TIMER SETTING, CONTACTORS ETC.
- CHECKING OIL LEVEL FOR THE COMPRESSOR.
- CHECKING THE STANDING PRESSURE, SUCTION &DISCHARGES PRESSURE OF REFRIGERATION SYSTEM SAND CROSS CHECKING OF THE PROPER FUNCTIONING OF REFRIGERATION SYSTEM.
- CHECKING OF COMPLETE ELECTRICAL WIRING IF ANY WIRE FOUND DAMAGED CORRECTIONS FOR THE SAME.
- FUNCTIONAL CHECKING OF INDIVIDUAL SYSTEM FOR PROPER CONTROL, SAFETY OPERATION ETC.
- CLEANING OF ALL LEVEL TANKS FILTERS ETC., FOR HUMIDITY SYSTEM IF APPLICABLE.
- CHECKING OF WATER LEVEL CONTROLLER OPERATION, CLEANING OF LEVEL SENSOR, CLEANING OF SCALING ON THE HEATER TUBE FOR HUMIDITY IF APPLICABLE.
- FILLING LOG SHEET AND SUBMITTING THE REPORT OF ANY ABNORMALITIES, FAILURES OBSERVED AND CORRECTED REPAIRS CARRIED OUT.
CLIMATIC CHAMBER MANUFACTURER